International Water Ski Federation 2001 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition:02S129B name of competition:Southern Regionals Championship 2002 Date:25/07/2002 28/07/2002 Venue:Ski Club of Palm Beachs, West Palm Beach, FL Organizing Country:USA, FLORDIA Type of competition (National ) Were cash prizes or merchandise awarded (Yes/No) (No ) Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom ( R) ( ) ( ) ( ) Tricks ( R) ( ) ( ) ( ) Jump ( R) ( ) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) ( ) Maunfacturer:PERFECT PASS Software Version:XY 6.3 slalom (OK) tricks (OK) jump (OK) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) ( ) slalom (OK) jump (OK) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (X ) 8. Automatic timing-jump (OK) Optional Timing Method ( ) 9. Jump distance indication (W 13.11) (OK) 10.Video Jump Distance measurement (W 13.11)(OK) Backup - video tape or standard meters (Video ) 11.Automatic timing-slalom Dual Segment (NA) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. 2 Towers x 2 Judges ( ) 2 Central Tower Judges (OK) Boat Video ( ) 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) (OK) 16.Position and height of trick towers (OK) (W 15.11) 16a. 5 Judges (OK) 1 x 3 Judges with video (NA) 2x 3 Judges with video (NA) 17.Semi-automatic timing-20sec (W 15.12) (OK) automatic median start (NA) 17a. Video Tricks Timing (NA) with Additional judge (OK) Chief Judge ( ) 18.VHS video tricks (W15.15) (OK) 19.7,000/10,000 points review judge (NA) (W 15.15) 17a.Video Tricks Timing system manufacturer (Accuski ) SLALOM COURSE TYPE :Cross-Wire JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (39.93 ) y (-10.07) Video system x (39.94 ) y (-10.37) 60m Test buoy Survey x (59.72 ) y (-10.86) Video system x (59.73 ) y (-11.10) JUMP RAMP Width at top (W 13.02a) 4.27 m Width at bottom 4.27 m Top edge to 6.4m line left side (W 13.02b,h) 6.4 m Top edge to 6.4m line right side (W 13.02b.h) 6.4 m Top edge to 6.7m line left side (W 13.02b,h) 6.7 m Top edge to 6.7m line right side (W 13.02b.h) 6.7 m Length underwater from 6.7m line (W 13.02c) .6 m Maximum Deviation from plane Diagonal string measurement (W 13.02f) 1.0 cm Center string measurement (W 13.02f) 1.0 cm (OK/X) Apron under water (W 13.02g) (OK) Apron full length (W 13.02g) (OK) Sighting line (W 13.02i) (OK) Secure anchoring (W 13.02i) (OK) Apron Angle (W 13.02k) jump height OK m (a) length of edge of apron from top corner to water OK m (b) ratio of b/a (X.XXX) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.59 6.76 0.235 1.59 6.76 0.235 1.65 1.74 6.80 0.256 1.74 6.80 0.256 1.80 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS Jim Salmas set a new M9 National Trick Record at 1370. Scott Ellis set a new M2 National Jump Record at 64.6M (212ft) Frankie Dees set a new M4 National Jump Record at 49.6M (163ft). Used 4 lakes, 2 slalom lakes on two of the days, 1 trick lake and 1 jump lake. Used Video Gates on two slalom lakes with no problems. Had two Slalom Switch used for the entire tourn. Found that the two switch were not working. The micro switch was not making up. Toke more that 300#. Reworked switch and verified that the switched function at 130# single line. Had no 10,000 trick points therefore did not require Trick Video timer. Only had 3 reviews that required Video re-review by judges. Trick lake had no problems. Used VJ (two computers, 3 grids). Jump lake had no problem. One of the computers with ATI All in Wonder Card locked up. Used a backup VJ computer that had a SE100 card. The computers with the SE100 Cards are clearer (not an overlay) and appears not to give any problems. Set the jump at 3.48 degrees open, some of the Juniors felt that it was too open, but all others had no problems and liked the jump setting. Tryed to reset jump height to 5'-0" at 21-9" for Men 6 thru 10 but could not because we did not have enough wieght to lower the low end in the water to maintain 1'-9". Seniors and Boy 3 jumped with jump setting at 5'-2" and 22'-0" (.2348). All others jumped at 5'-3" and 5-8" Need to change rules on jump height for older jumpers. NO TECHNICAL PROBLEMS ENCOUNTERED. Homologator: Jerry Jackson 3844 Creek Court Augusta, GA. 30907 SlalomJJ@aol.com 706-868-9240 Chief Judge: Bill Wermer FL This homologation record has been emailed to bcorson@home.com for EAME: email also to abottinelli@bluewin.ch ----------------------------------------------------------------------------- To be posted before the tournament starts HOMOLOGATION NOTICE Tournament Name:Southern Regionals Championship 2002 Date:25/07/2002 28/07/2002 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (R) ( ) ( ) ( ) Tricks (R) ( ) ( ) ( ) Jump (R) ( ) ( ) ( ) Speed Control Manufacturer:PERFECT PASS Software Version:XY 6.3 Mode for tricks (if applicable):Classic Date _________ ________ _______ Time _________ ________ _______ Chief Judge Homologator ____________________ ________________ Note: These recomendations may change during the competition. Remarks: End of Document