[Classic Dossier] Element=etClassicDossier International Water Ski Federation 2005 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition:05S117R name of competition:47th Masters & Jr Masters Water Ski Tournament Date:5/27/05 5/29/05 Venue:Callaway Gardens, Pine Mountain, GA, USA Organizing Country:USA Type of competition (International Non-Calendar ) Were cash prizes or merchandise awarded (Yes/No) (Yes ) Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom ( R) ( R) ( R) ( R) Tricks ( R) ( R) ( R) ( R) Jump ( R) ( R) ( R) ( R) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) ( ) Maunfacturer:Perfect Pass Software Version:6.5 & 6.5DBW slalom (OK) tricks (OK) jump (OK) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) ( ) slalom (OK) jump (OK) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (X ) 8. Automatic timing-jump (OK) Optional Timing Method (NA) 9. Jump distance indication (W 13.11) (OK) 10.Video Jump Distance measurement (W 13.11)(OK) Backup - video tape or standard meters (Video ) 11.Automatic timing-slalom Dual Segment (NA) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. Slalom Officials: 1 boat judge + 4 judges, 2 on each side of the lake (W 14.13) 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) (OK) 16.Position and height of trick towers (OK) (W 15.11) 16a. 5 Judges (OK) 1 x 3 Judges with video (NA) 2x 3 Judges with video (OK) 17.Semi-automatic timing-20sec (W 15.12) (NA) automatic median start (NA) 17a. Video Tricks Timing (OK) with Additional judge (OK) Chief Judge ( ) 18.VHS video tricks (W15.15) (OK) 19a.Video Tricks Timing system manufacturer (Bob Corson VT 2004 ) SLALOM COURSE TYPE :Single anchor buoys JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (38..42) y (-13.77) Video system x (4515 ) y (6360 ) 60m Test buoy Survey x (59.91 ) y (-12.46) Video system x (5265 ) y (5700 ) JUMP RAMP Width at top (W 13.02a) X.XX m Width at bottom X.XX m Top edge to 6.4m line left side (W 13.02b,h) X.XX m Top edge to 6.4m line right side (W 13.02b.h) X.XX m Top edge to 6.7m line left side (W 13.02b,h) 6.8 m Top edge to 6.7m line right side (W 13.02b.h) 6.8 m Length underwater from 6.7m line (W 13.02c) X.XX m Maximum Deviation from plane Diagonal string measurement (W 13.02f) 0 cm Center string measurement (W 13.02f) 0 cm (OK/X) Apron under water (W 13.02g) (OK) Apron full length (W 13.02g) (OK) Sighting line (W 13.02i) (OK) Secure anchoring (W 13.02i) (OK) Apron Angle (W 13.02k) jump height X.XX m (a) length of edge of apron from top corner to water X.XX m (b) ratio of b/a (X.XXX) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.60 6.8 0.235 1.61 6.8 0.237 1.65 1.73 6.8 0.254 1.73 6.8 0.254 1.80 1.85 6.8 0.272 1.85 6.8 0.272 NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS No Technical Issues. Jump: Measured using Bob Corson Video Capture/Measuring 2005 System without any problems. Two Jump Course were setup for jumping North and South. North Grid was modified on Friday (5/27/05) after Jr round. The Survey Program (V3.3) was used to calculate X and Y position. The new calculated X and Y positions were input into the Video Jump program (VJN1A.IPT, VJN2.IPT). However, the new survey points were not saved in the survey spread sheet (Jmpsurvn). Men Jump Record: Feddy Krueger jumped 72.5 Meters (238 Ft)in the finals (5/29/05)(jumping North) for a new World and National Record. Tricks: Timed used Bob Corson 2004 Trick Timer Program; had to change the Video Compression from "Indeo Video 5.04 Compression Filter" to "Indeo Video 4.3". Had no major problem after that. Tricks were judged by 5 judges from 3 TVs with input from from a stationary camera mounted on boat (Mr. Mirror). The video was transmitted to the trick timer computer and VCR/TVs. The judges immediate re-review each pass using VCR. A shore camera was also used for back up (timer/judge) but was not needed Slalom: North Gate was transmitted to officials located between buoy 3 and 4 with video review if required. The two officials on far tower (44 degrees) also had gate video review if required. The HDTV camera in the boat had no means of transmitting a composite (RCA) signal output. We were not able to capture boat video for the officials to review. However, we did capture video from shore for backup. Homologator: Jerry Jackson Gene Davis Dave Clark Dee Johnson Email:SlalomJJ@Netzero.net Chief Judge: Nikki Lee This homologation record has been emailed to Bob Corson, bcorson@comcast.net for EAME: email also to Marc Raymond, SKIRAYMO@aol.com HOMOLOGATION NOTICE Tournament Name:47th Masters & Jr Masters Water Ski Tournament Date:5/27/05 5/29/05 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (R ) (R ) (R ) (R ) Tricks (R ) (R ) (R ) (R ) Jump (R ) (R ) (R ) (R ) Speed Control Manufacturer:Perfect Pass Software Version:6.5 & 6.5DBW Mode for tricks (if applicable):Classic Date _________ ________ _______ Time _________ ________ _______ Chief Judge Homologator ____________________ ________________ Note: These recommendations may change during the competition. Remarks: 6.5DBW